INICIOCENTRO MÉDICO LASERLOCALIZACIÓNCONTACTOÁREA CIENTÍFICAÁREA TECNOLÓGICAPUBLICACIONES

Láser Medlite-Conbio

The Medlite IV Q-Switched, ND:YAG Laser

Continuum Biomedical is proud to announce a new generation Medlite Q-Switched, Frequency Doubled, Nd:YAG Laser... 

Breakthrough technological advances, developed by the new ConBio medical engineering team, have produced a Q-Switched ND:YAG with greater than twice the power of the current Medlite model. 

Along with this significant power increase, are the added features of both improved beam quality and larger spotsizes. These new features combine to provide the most advanced and highest power Q-Switched ND:YAG laser available in the medical marketplace today. 

A unique feature of the Medlite is its clearance for multiple diverse applications. Originally introduced as a tattoo removal laser, ConBio has diligently poured research funding into defining new applications, constantly increasing the Medlite's practicality for the office environment. 

Introduced in late 1991, over 300 units have been sold worldwide. The Medlite's reliability combined with it's multiple applications have earned it the renowned label of a real "workhorse". Leading researchers have gone so far as to say. "If you can only afford one laser in your practice, the Q-Switched, ND:YAG is the laser of choice". 

Twice as powerful, the new Medlite IV offers expanded treatment applications. The Medlite IV includes Multilite? accessory handpieces, providing two additional wavelengths at 585 & 650 nm -- four wavelengths from one laser.

Applications

*    Hair Removal
*    Tattoo Ink - Black, Red & Green
*    Dermal & Epidermal Pigmented Lesions
*    Vascular Lesions 

Featuring

*    Increased Power
*    Larger Spotsizes
*    Uniform Beam

Dark & Red Tattoo Ink Removal

Professional dark ink tattoos require an average of 4 - 8 treatments with the 1064 nm wavelength to remove deep ink. "Homemade" tattoos usually require only 2 - 4 treatments. Red ink, readily absorbed by the 532 nm wavelength, typically requires only one or two treatments. Treatments are spaced 6 - 8 weeks apart.

Epidermal Pigmented Lesion Treatment

Most lesions are removed in only one treatment, with a healing time of 2 - 4 weeks. The risk of hypopigmentation is extremely low. Transient hyperpigmentation is evident in a small percentage of patients, usually showing prior susceptibility, but typically resolving in less than 2-3 months.

Dermal Pigmented Lesion Treatment

Thousands of dermal melanocytosis cases, including Nevus of Ota and Mongolian Spot, have been treated at 1064 nm with extreme success.

Vascular Lesion Treatment

The 532 nm wavelength treats telangiectacia through to portwine stain. Purpura resolves quickly, typically in less than one week.

FEATURES OF THE MEDLITE? IV LASER

Multilite Dye Laser Handpiece 

The increased power of the Medlite IV opens the door to the use of this exciting new product... The Multilite Dye Laser Handpiece. 

A dye impregnated polymer rod converts the 532 nm Medlite IV wavelength to either 585 nm or 650 nm. These new wavelengths are expected to increase treatment applications in the areas of tattoo ink removal (green and light blue inks), vascular lesions and pigmented lesions. With the addition if these completely solid state handpieces, the Medlite IV effectively includes four wavelengths in one laser. 

Increased Power 

The Medlite IV power has increased from 450 millijoules to an astounding high of greater than 1000 millijoules (1.0 Joule) at 1064 nm (infrared). The green wavelength at 532 nm has increased from under 200 mJ to over 400 mJ. 

Larger Spotsizes

These high powers enable the Medlite IV to utilize new larger spotsizes. The 1064 nm wavelength will have 3, 4, 6, and 8mm spotsizes and 532 nm will have 2, 3, 4, and 6mm. Of course, larger spotsizes can reduce treatment times by increasing the area covered per pass. Additionally, research has shown larger spotsizes to cause less skin debris during treatment. New treatment endpoints, with the use of larger spotsizes, call for treating to a crisp whitening and avoiding pinpoint bleeding. 

Uniform Beam 

New optical configurations have increased the beam uniformity for optimal energy density distribution throughout the entire spotsize. 

Electrical Specifications 

Incredibly, this major jump in laser energy is available with no increase to electrical input specifications. The Medlite IV still only requires 110V and 12 Amp electrical service, standard in any office.

Multilite Dye Laser Handpiece System

Pumped with the Medlite IV or Medlite II Q-Switched Nd:YAG Laser at 532 nm 

The increased power of the Medlite IV opens the door to the use of this exciting new product... The Multilite Dye Laser Handpiece. 

A dye impregnated polymer rod converts the 532 nm Medlite IV wavelength to either 585 nm or 650 nm.
These new wavelengths are expected to increase treatment applications in the areas of tattoo ink removal (green and light blue inks), vascular lesions and pigmented lesions. With the addition if these completely solid state handpieces, the Medlite IV effectively includes four wavelengths in one laser.

Gracia por su interés.
No dude en contactar con nosotros para resolver cualquier duda que pudiera 
planteársele al respecto.

  Última actualizacion web 24-10-2011